  1. Solid or stranded for dc - Mike Holt's Forum

    May 5, 2008 · I ran 10-2 w/g solid uf wire from the e-panel to the solar panels. I'll not mention the load on the wire or the distance or the temperature because I don't want to side track the …

  2. solid vs stranded THHN | Information by Electrical Professionals for ...

    Nov 4, 2019 · I find stranded is easier to shove into the boxes But stranded wire is a bit slower to make up at the devices, and can be unwieldy pulling in, as it wants to jump off the spools. …

  3. Bare Solid vs Bare Stranded Ground Wire | Information by …

    Oct 3, 2008 · Can you offer some Pros and Cons regarding the use of Bare Solid and Bare Stranded Equipment Grounding conductors in PVC Underground conduit?

  4. solid vs stranded thhn | Information by Electrical Professionals for ...

    Jan 17, 2018 · Is there any preference between using stranded vs solid thhn below #6 in a boiler house environment where there is no movement, that is, fixed situation. Where we are, solid is …

  5. Solid vs. Stranded wiring? - Fine Homebuilding

    May 16, 2004 · I was told today that stranded 10 gauge copper wire will carry more current than solid of the same gauge and material. Is this true? Thanks in advance. Pete Duffy, […]

  6. stranded vs. solid wire | Information by Electrical Professionals for ...

    Oct 19, 2003 · Re: stranded vs. solid wire well what prompted me to start this post was that because the HFC was a special order cause it had to be steel jacketed by spec and i wanted …

  7. Stranded versus solid bare Number 6 | Information by Electrical ...

    Jun 29, 2020 · Just a general question as for grounding when is it more acceptable to use stranded number 6 copper for grounding versus bare number 6 when connecting a solar array …

  8. Stranded VS Solid | Information by Electrical Professionals for ...

    Sep 7, 2010 · What are the advantages and disadvantages of using stranded or solid wire for 20 branch circuits in residential custom homes? Some foreman are convienced that stranded is …

  9. Fire alarm wire is always solid | Information by Electrical ...

    Jan 22, 2010 · Fire alarm wire is always solid, Why? I cannot remember why. Fire alarm wire is always solid, Why? I cannot remember why. I think it is tradition while the NEC says stranded …

  10. Branch Wire: Solid vs Stranded | Information by Electrical ...

    May 26, 2022 · Hey everyone, I need some help convincing an electrical engineer to allow us to install stranded #12 AWG & #10 AWG branch wire. For some context the project is a large …